> Email us HomeSite Map | Japan Site Japan Site
Go to Horizon Home


WARRANTY
Downloads:
H-Series
> Brochure

Share:


Fuel Cells


World-leading fuel cell performance at the world's lowest cost

When looking to procure larger-scale fuel cells for product development or system integration, you are likely to find the best possible value at Horizon Fuel Cell Technologies. We offer the widest range of standard "off-the-shelf" PEM fuel cell systems today from 10W to 5kW (deliverable within 1 to 4 weeks), as well as customized fuel cell system configurations up to 30kW. Our standard systems are simple, efficient, and feature some of the highest power densities available in the world - opening new possibilities for integration and commercialization.

The Horizon Fuel Cell advantage:
*Comparison based on the 1.2kW NEXA system from Ballard.

Our standard systems specifications below will guide you through our off-the-shelf product line. For more information or if you would like a configuration not listed here, please contact us at stacks@horizonfuelcell.com
  • Lower cost
  • High efficiency
  • Lighter weight
  • Smaller size
  • Simple to use
  • Easy to integrate
  • Reduced peripherals
  • Increased reliability
  •  


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells......................................................13
    Rated power.......................................................12W
    Rated Performance..... .............................7.8V@1.5A
    Purging valve voltage.............................................6V
    Blower voltage.......................................................5V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................55°C(131°F)
    Hydrogen pressure.................................0.45-0.55Bar
    Humidification....................................Self-humidified
    Cooling..............................Air (integrated cooling fan) Stack Weight (with fan & casing)................275g(±30g)
    Stack Size............................75x47x70mm(3x1.8x2.8in)
    Flow rate at max output..............................0.18L/min
    Hydrogen purity..............................≥99.995% dry H2
    Start up time.................≤30s(ambient temperature)
    Efficiency of system..........................40% at full power
    Order Now!


    Semi-integrated 12W fuel cell system

    Including:

    •Integrated fan and casing
    •12W stack with blower
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 

    Type of fuel cell....................................................PEM
    Number of cells......................................................13
    Rated power.......................................................20W
    Rated Performance..... .............................7.8V@2.6A
    Purging valve voltage.............................................6V
    Blower voltage.......................................................5V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................55°C(131°F)
    Hydrogen pressure.................................0.45-0.55Bar
    Humidification....................................Self-humidified
    Cooling..............................Air (integrated cooling fan) Stack Weight (with fan & casing)................275g(±30g)
    Controller weight.........................................90g(±10g)
    Stack Size............................75x47x70mm(3x1.8x2.8in)
    Flow rate at max output..............................0.28L/min
    Hydrogen purity..............................≥99.995% dry H2
    Start up time.................≤30s(ambient temperature)
    Efficiency of system..........................40% at full power

    Order Now!


    Semi-integrated 20W fuel cell system

    Including:

    •Miniature electronic valve
    •Control electronics
    •Integrated fan and casing
    •Low pressure protection
    •20W stack with blower
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 

    Type of fuel cell....................................................PEM
    Number of cells......................................................14
    Rated power.......................................................30W
    Rated Performance..... .............................8.4V@3.6A
    Purging valve voltage.............................................6V
    Blower voltage.......................................................5V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................55°C(131°F)
    Hydrogen pressure.................................0.45-0.55Bar
    Humidification....................................Self-humidified
    Cooling..............................Air (integrated cooling fan) Stack Weight (with fan & casing)................280g(±30g)
    Controller weight.........................................90g(±10g)
    Stack Size............................80x47x75mm(3.1x1.8x3in)
    Flow rate at max output..............................0.42L/min
    Hydrogen purity..............................≥99.995% dry H2
    Start up time.................≤30s(ambient temperature)
    Efficiency of system..........................40% at full power

    Order Now!


    Semi-integrated 30W fuel cell system

    Including:

    •Miniature electronic valve
    •Control electronics
    •Integrated fan and casing
    •Low pressure protection
    •30W stack with blower
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 

    Type of fuel cell....................................................PEM
    Number of cells......................................................24
    Rated power......................................................100W
    Rated Performance..... ............................14.4V@7.2A
    Hydrogen supply valve voltage..... ........................12V
    Purging valve voltage............................................12V
    Blower voltage......................................................12V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure.................................0.45-0.55Bar
    Humidification....................................Self-humidified
    Cooling..............................Air (integrated cooling fan) Stack Weight (with fan & casing)................960g(±50g)
    Controller weight.......................................400g(±30g)
    Stack Size.....................130x112x95mm(5.1x4.4x3.7in)
    Flow rate at max output................................1.4L/min
    Hydrogen purity..............................≥99.995% dry H2
    Start up time.................≤30s(ambient temperature) Efficiency of system.................................40% @14.4V
    Low voltage protection.........................................12V Over current protection........................................12A Over temperature protection..............................65°C External power supply.........................13V( ±1V), <5A

    Order Now!


    Semi-integrated 100W fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •100W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells......................................................48
    Rated power.....................................................200W
    Rated Performance..... ...........................28.8V@7.2A
    Hydrogen supply valve voltage..... .......................12V
    Purging valve voltage...........................................12V
    Blower voltage.....................................................12V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure.................................0.45-0.55Bar
    Humidification....................................Self-humidified
    Cooling..............................Air (integrated cooling fan) Stack Weight (with fan & casing)............1550g (±50g)
    Controller weight......................................400g(±30g)
    Stack Size....................215x112x95mm(8.5x4.4x3.7in)
    Flow rate at max output...............................2.8L/min
    Hydrogen purity..............................≥99.995% dry H2
    Start up time..................≤30s(ambient temperature) Efficiency of system...................................40% @28V
    Low voltage protection........................................24V Over current protection.......................................12A Over temperature protection.............................65°C External power supply........................13V( ±1V), <5A
    Order Now!


    Semi-integrated 200W fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •200W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells......................................................72
    Rated power.....................................................300W
    Rated Performance..... ..............................43.2V@7A
    Hydrogen supply valve voltage..... .......................12V
    Purging valve voltage...........................................12V
    Blower voltage.....................................................12V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure................................0.45-0.55Bar
    Humidification...................................Self-humidified
    Cooling.............................Air (integrated cooling fan) Stack Weight (with fan & casing)............2050g (±50g)
    Controller weight......................................400g(±30g)
    Stack Size....................280x112x95mm(11x4.4x3.7in)
    Flow rate at max output...............................4.2L/min
    Hydrogen purity.............................≥99.995% dry H2
    Start up time..................≤30s(ambient temperature) Efficiency of system................................40% @43.2V
    Low voltage protection........................................36V Over current protection.......................................12A Over temperature protection.............................65°C External power supply........................13V( ±1V), <5A
    Order Now!


    Semi-integrated 300W fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •300W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells......................................................36
    Rated power.....................................................500W
    Rated Performance..... ............................21.6V@24A
    Hydrogen supply valve voltage..... .......................12V
    Purging valve voltage...........................................12V
    Blower voltage.....................................................12V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure................................0.45-0.55Bar
    Humidification...................................Self-humidified
    Cooling.............................Air (integrated cooling fan) Stack Weight (with fan & casing)............2800g (±50g)
    Controller weight......................................400g(±30g)
    Stack Size..................215x125x180mm(8.5x4.9x7.1in)
    Flow rate at max output..................................7L/min
    Hydrogen purity..............................≥99.995% dry H2
    Start up time...................≤30s(ambient temperature) Efficiency of system................................40% @21.6V
    Low voltage protection........................................18V Over current protection.......................................30A Over temperature protection.............................65°C External power supply........................13V( ±1V), <5A
    Order Now!


    Semi-integrated 500W fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •500W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells......................................................72
    Rated power...................................................1000W
    Rated Performance..... ............................43.2V@24A
    Hydrogen supply valve voltage..... .......................12V
    Purging valve voltage...........................................12V
    Blower voltage.....................................................12V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure................................0.45-0.55Bar
    Humidification...................................Self-humidified
    Cooling.............................Air (integrated cooling fan) Stack Weight (with fan & casing)...........4.5kg (±100g)
    Controller weight......................................400g(±30g)
    Stack Size................215x125x300mm(8.5x4.9x11.8in)
    Flow rate at max output................................14L/min
    Hydrogen purity..............................≥99.995% dry H2
    Start up time..................≤30s(ambient temperature) Efficiency of system................................40% @43.2V
    Low voltage protection........................................36V Over current protection.......................................30A Over temperature protection.............................65°C External power supply......................13V( ±1V), 5A-8A
    Order Now!


    Semi-integrated 1000W fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •1000W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells......................................................48
    Rated power...................................................2000W
    Rated Performance..... ............................28.8V@70A
    Hydrogen supply valve voltage..... .......................12V
    Purging valve voltage...........................................12V
    Blower voltage.....................................................12V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure................................0.45-0.55Bar
    Humidification...................................Self-humidified
    Cooling.............................Air (integrated cooling fan) Weight (with fan & casing)...........about 10000 grams
    Controller weight..................................2500g(±100g)
    Stack Size..............approx. 40.4cm x 18.3cm x 32.7cm
    Flow rate at max output................................29L/min
    Hydrogen purity.............................≥99.995% dry H2
    Start up time..................≤30s(ambient temperature) Efficiency of system................................40% @28.8V
    Low voltage protection........................................24V Over current protection.......................................90A Over temperature protection.............................65°C External power supply.......................13V( ±1V), 5A-8A
    Order Now!


    Semi-integrated 2000W fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •2000W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells......................................................72
    Rated power...................................................3000W
    Rated Performance..... ............................43.2V@70A
    Hydrogen supply valve voltage..... .......................12V
    Purging valve voltage...........................................12V
    Blower voltage.....................................................12V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure................................0.45-0.55Bar
    Humidification...................................Self-humidified
    Cooling.............................Air (integrated cooling fan) Weight (with fan & casing)...........about 15000 grams
    Controller weight..................................2500g(±100g)
    Stack Size...............approx. 40.4cm x 18.3cm x 44.9cm
    Flow rate at max output................................42L/min
    Hydrogen purity..............................≥99.995% dry H2
    Start up time..................≤30s(ambient temperature) Efficiency of system................................40% @43.2V
    Low voltage protection........................................36V Over current protection.......................................90A Over temperature protection.............................65°C External power supply.......................13V( ±1V), 5A-8A
    Order Now!


    Semi-integrated 3000W fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •3000W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells....................................................120
    Rated power...................................................5000W
    Rated Performance..... ...............................72V@70A
    Hydrogen supply valve voltage..... .......................12V
    Purging valve voltage...........................................12V
    Blower voltage.....................................................24V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-30°C(41-86°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure................................0.45-0.55Bar
    Humidification...................................Self-humidified
    Cooling.............................Air (integrated cooling fan) Weight (with fan & casing)...........about 30000 grams
    Controller weight..................................2500g(±100g)
    Stack Size..............approx. 40.4cm x 21.2cm x 69.2cm
    Flow rate at max output................................70L/min
    Hydrogen purity.............................≥99.995% dry H2
    Start up time..................≤30s(ambient temperature) Efficiency of system...................................40% @72V
    Low voltage protection........................................60V Over current protection.......................................90A Over temperature protection.............................65°C External power supply.....................24V( ±1V), 8A-12A
    Order Now!


    Semi-integrated 5000W fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •5000W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
     


    H-12
    H-20
    H-30
      H-100
      H-200
      H-300
      H-500
     H-1000
    H-1000XP 
    H-2000
    H-3000
    H-5000 
    Type of fuel cell....................................................PEM
    Number of cells......................................................50
    Rated power...................................................1000W
    Rated Performance..... .............................30V@33.3A
    Hydrogen supply valve voltage..... .......................12V
    Purging valve voltage...........................................12V
    Blower voltage.....................................................12V
    Reactants........................................Hydrogen and Air
    Ambient temperature........................5-35°C(41-95°F)
    Max stack temperature............................65°C(149°F)
    Hydrogen pressure................................0.45-0.55Bar
    Humidification...................................Self-humidified
    Cooling.............................Air (integrated cooling fan) Stack Weight (with fan & casing)............Approx.3.6kg
    Controller weight..................................Approx.1.9kg
    Stack Size................264x197x117mm(10.4x7.8x4.6in)
    Flow rate at max output.............................13.5L/min
    Hydrogen purity...............................≥99.995% dry H2
    Start up time......................................................≤30s
    Efficiency of system.....................48% @30V LHV (net)
    Low voltage protection........................................25V Over current protection.......................................50A Over temperature protection.............................68°C Start up battery...................................................12V
    Order Now!


    Semi-integrated 1kW fuel cell system

    Including:

    •Connections/Tubing
    •Electronic valves
    •Electronic control box
    •1000W stack with blower
    •Fuel cell ON/OFF switch
    •SCU ON/OFF switch
    Enquire here!